XS Instruments COND80+
Gyártó: | XS Instruments |
Cikkszám: | XS Instruments COND80+ |
Elérhetőség: | Előrendelhető |
COND measuring range 0,00…20,00 - 200,0 - 2000 μS / 2,00 - 20,00 - 200,0 - 1000 mS
Resolution Automatic scale
Accuracy ±1 % full scale
COND calibration points 1…4
|
Leírás és Paraméterek
COND measuring range 0,00…20,00 - 200,0 - 2000 μS / 2,00 - 20,00 - 200,0 - 1000 mS
Resolution Automatic scale
Accuracy ±1 % full scale
COND calibration points 1…4
Buffer auto recognition 84, 1413 μS, 12.88, 111.8 mS, 1 defined by the user
Indication of calibration points Yes
Temperature coefficent Ultrapure Water and 0,00…10,00 %/°C
Reference temperature 15…30ºC
GLP calibration Yes, with date and time
Indication of conditions of the cell Yes, with icon
Indication of cell constant Yes
Calibration timer with alarm Yes
Cell type 2 poles
Cell constant 0,1 - 1 - 10
TDS measuring range 0,1 mg/l…500g/l
TDS Factor/ Accuracy 0.40 … 1.00 / ±1 % full scale
Salinity measuring range / Accuracy 0,01…100 ppt / ±1 % full scale
Resistivity measuring range / Accuracy 1…10 MΩ / ±1 % full scale
Temperature °C measuring range / Accuracy -10…110,0 / ± 0,5°C
Temperature compensation Automaric or Manual 0…100°C (NTC 30KΩ)
Temperature calibration Yes
• Simultaneous display of COND/TDS/Salinity/Resistivity and temperature
• Resolution: automatic scale - Selectable cell constant allows to use with 2 plates cell
• Alphanumeric password for calibration management and data memory delete with soft keypad included
• GLP and IQ-OQ manual available
• Saving and recall calibration for each cell constant
• Automatic calibration from 1 to 4 calibration points, between 4 standard buffer solutions
• Manual calibration on 1 point (defined by the user)
• Wide colored display with indication of calibration standards solutions used and measurement’s stability
• Automatic and manual temperature compensation, reference values 15…30°C
• Compensation for Ultrapure water for low conductivity measurement
• Memory recall of last calibration, date, time and informations about the cell constant
• Calibration Timer: set frequency of the calibration for high quality of measurements
• Indication of stability
• Non-volatile memory holds up to 1000 data , with date and time, automatically (Data logger) or manually, and downloadable on PC with free software “DataLink”or printable
• Stirrer plate included (in stirrer version)
• 2 USB ports, for PC connection, and for external keyboard included
• RS232 port for printer connection
• Multilanguage menu setup
• Quick on-line manual
• 3 years warranty
COND measuring range 0,00…20,00 - 200,0 - 2000 μS / 2,00 - 20,00 - 200,0 - 1000 mS | |
Resolution Automatic scale | |
Accuracy ±1 % full scale | |
COND calibration points 1…4 | |
Buffer auto recognition 84, 1413 μS, 12.88, 111.8 mS, 1 defined by the user | |
Indication of calibration points Yes | |
Temperature coefficent Ultrapure Water and 0,00…10,00 %/°C | |
Reference temperature 15…30ºC | |
GLP calibration Yes, with date and time | |
Indication of conditions of the cell Yes, with icon | |
Indication of cell constant Yes | |
Calibration timer with alarm Yes | |
Cell type 2 poles | |
Cell constant 0,1 - 1 - 10 | |
TDS measuring range 0,1 mg/l…500g/l | |
TDS Factor/ Accuracy 0.40 … 1.00 / ±1 % full scale | |
Salinity measuring range / Accuracy 0,01…100 ppt / ±1 % full scale | |
Resistivity measuring range / Accuracy 1…10 MΩ / ±1 % full scale | |
Temperature °C measuring range / Accuracy -10…110,0 / ± 0,5°C | |
Temperature compensation Automaric or Manual 0…100°C (NTC 30KΩ) | |
Temperature calibration Yes |